Back to RecallTracker
Transport Canada Vehicles

2004 Fleetwood Wilderness Travel Trailer Recall

Issued March 25, 2004
Issue
Hazard description
On certain conventional and fifth wheel travel trailers, the 30-20 Amp double circuit breaker in the main panel was mis-marked and therefore incorrectly installed. This double breaker consists of a 1-pole 30 Amp breaker and a 1-pole 20 Amp breaker. These breakers may have been manufactured with the handle for the 30 Amp marked as "20" and the 20 Amp marked as "30". A 30 Amp circuit connected to a 20 Amp breaker might experience nuisance tripping. A 20 Amp circuit connected to a 30 Amp breaker, if fully loaded in a sustained overload condition, may result in overheated conductors, which could cause a risk of personal injury and/or property damage. Correction: Dealer will inspect, and replace the 30-20 Amp double circuit breaker as required.
Vehicle
FLEETWOOD WILDERNESS TRAVEL TRAILER