Back to RecallTracker
Transport Canada Vehicles

2010–2012 Altec Ah Series Recall

Issued July 22, 2014
Issue
Hazard description
On certain aerial devices installed on utility service vehicles (to elevate personnel in order to facilitate working on overhead service lines, for tree trimming, etc.), water ingress into the lower boom fiberglass inserts could allow a conductivity path through the boom from the boom elbow down to the chassis. If the boom elbow were to come in contact with, or in close proximity to, an energized conductor while persons on the ground are touching or in close proximity to the chassis, an increased risk of injury due to electrocution would result. Water ingress could also compromise the fiberglass insert glue joint, potentially leading to undesirable boom motion due to looseness of the joint, which could increase the risk of injury and/or damage to property. Correction: Altec will replace affected lower booms. Owners may contact Altec at 1-877-462-5832.
Vehicle
ALTEC AH SERIES